Numerical Simulation of Flow in Rotor-Casing Gap of a Rotary Piston Flow Meter

E. von Lavante, S. Poggel, H. Kaya, M. Franz
Abstract:
In the theoretical assessment of accuracy of rotary piston meters, the leakage flow in the rotor-casing gap is of essential importance. The present work aimed at detailed investigation of this flow field employing realistic numerical flow simulation. The resulting flow displayed significant differences to the simple assumption.
Keywords:
rotary flow meter, flowrate, numerical flow simulation, leakage flow, unsteady flow
Download: