INVESTIGATION OF THE CALIBRATION AND MEASUREMENT CAPABILITIES OF THE NEW 5 kN·m TORQUE CALIBRATION MACHINE AT GUM |
|---|
| Mikołaj Woźniak, Dirk Röske |
- Abstract:
- A new torque calibration machine with a torque capacity of 5 kN·m has been installed in Force and Pressure Laboratory of GUM. This reference type machine generates torques in vertical axis in a range from 10 N·m to 5 kN·m with an expanded relative measurement uncertainty of 0,04 % (k = 2). Performance of the machine has been evaluated via comparison between GUM and PTB. Results of comparison measurement are presented.
- Keywords:
- torque, torque calibration machine, comparison
- Download:
- IMEKO-WC-2015-TC3-092.pdf
- DOI:
- -
- Event details
- Event name:
- XXI IMEKO World Congress
- Title:
Measurement in Research and Industry
- Place:
- Prague, CZECH REPUBLIC
- Time:
- 30 August 2015 - 04 September 2015