REALIZATION OF THE INDUCTANCE STANDARD AT CEM |
|---|
| Y. A. Sanmamed, A. Sánchez, K. Schweiger, J. Díaz de Aguilar, R. Caballero,M. Neira |
- Abstract:
- Inductance has been realized at Spanish Centre of Metrology (CEM) by means of a modified coaxial Maxwell-Wien bridge. This method ensures inductance traceability from the SI unit of capacitance and establishes the value of the CEM’s set of 10 mH standard inductors at the frequency of 1 kHz.
- Keywords:
- Inductance, capacitance, resistance, impedance bridge
- Download:
- IMEKO-TC4-2011-030.pdf
- DOI:
- -
- Event details
- IMEKO TC:
- TC4
- Event name:
- TC4 Symposium 2011
- Title:
XVIIIth IMEKO TC4 International Symposium on Measurement of Electrical Quantities (part of Metrologia2011, together with IX International Congress on Electrical Metrology - IX SEMETRO)
- Place:
- Natal, BRAZIL
- Time:
- 27 September 2011 - 30 September 2011