MEASUREMENT OF WBGT INDEX IN AXIAL FLOW AS THE MAIN THERMODYNAMIC PARAMETERS VARY

G. Buonanno, M. Dell'Isola, A. Frattolillo, L. Vanoli
Abstract:
Heat stress is a common problem throughout industry that depends also on some climatic parameters, such as the mean radiant temperature, air humidity, velocity and temperature. WBGT (wet bulb globe temperature) index is assumed in international standards as thermal stress index in job environments. It can be estimated directly, following the ISO 7243, by means of globe temperature, natural wet-bulb temperature and air temperature measurements or indirectly by means air temperature, humidity and velocity, and the radiative medium temperature. The aim of the present work is the experimental comparison between the two different methodologies to evaluate the WBGT index. The analysis is carried out in a wide range of thermodynamic properties and also for air velocity less than 0.5 m s-1.
Keywords:
WBGT, natural wet bulb thermometer, globe thermometer, axial flow
Download:
IMEKO-WC-2000-TC12-P302.pdf
DOI:
-
Event details
Event name:
XVI IMEKO World Congress
Title:

Measurement - Supports Science - Improves Technology - Protects Environment ... and Provides Employment - Now and in the Future

Place:
Vienna, AUSTRIA
Time:
25 September 2000 - 28 September 2000