MULTIPATH CROSS-CORRELATION FLOWMETERS

V. Skwarek, V. Hans
Abstract:
The ultrasonic cross-correlation flowmeter is not only a reliable measurement device due to recent improvements in signal processing; it can even be used for gaining further knowledge about the properties of turbulent flow. This paper shows as well considerations about fluctuations, measuring time and ergodicity as arrangements and necessities for multi path measurements. Results are used for averaging and first tomographic approaches for the visualization of turbulent flow.
Keywords:
ultrasonic cross-correlation flowmeter, multi path measurement, ergodicity, tomography
Download:
IMEKO-WC-2000-TC9-P249.pdf
DOI:
-
Event details
Event name:
XVI IMEKO World Congress
Title:

Measurement - Supports Science - Improves Technology - Protects Environment ... and Provides Employment - Now and in the Future

Place:
Vienna, AUSTRIA
Time:
25 September 2000 - 28 September 2000