HIGH RESISTANCE COMPARISON AMONG KRISS, VNIIM AND NIM |
|---|
| K. M. Yu, J. C. Ryu, Y. P. Semenov, B. Litvinov, S. Haiming |
- Abstract:
- In a high resistance comparison among KRISS, VNIIM and NIM, the relative resistance values of measurement results agreed well within 2 ppm in 10 megohm and 5 ppm in 1 gigohm. Also, relative combined standard uncertainties of the three institutes for the values is not beyond 4 ppm in 10 megohm and 8 ppm in 1 gigohm.
- Keywords:
- high resistance comparison, 10 megohm and 1 gigohm, adapted Wheatstone bridge, binary voltage divider bridge
- Download:
- IMEKO-WC-2000-TC8-P230.pdf
- DOI:
- -
- Event details
- Event name:
- XVI IMEKO World Congress
- Title:
Measurement - Supports Science - Improves Technology - Protects Environment ... and Provides Employment - Now and in the Future
- Place:
- Vienna, AUSTRIA
- Time:
- 25 September 2000 - 28 September 2000