LONG-TERM STABILITY OF THE IMGC REFERENCE FORCE TRANSDUCERS UP TO 9 MN

C. Ferrero, C. Marinari
Abstract:
Force transducers are calibrated using dead-weight, lever multiplication or hydraulic multiplication standard machines. For very large capacities, in general above 1 MN, the "build-up" method may be employed, consisting of comparing the dynamometer to be calibrated with one or more dynamometers linked in parallel. With the "build-up" method the field of force measurement may be extended to values that would not appear possible with the use of dead-weight or multiplication primary standards, at a much lower cost. The present paper reports the evolution over time, that is the long term stability of the metrological characteristics (calibration factors, repeatability, hysteresis and zero variations at no load) of two reference transducers (3 MN and 9 MN respectively) used to calibrate force transducers at IMGC-CNR.
Download:
IMEKO-TC3-2001-023.pdf
DOI:
-
Event details
IMEKO TC:
TC3
Event name:
TC3 Conference 2001
Title:

17th Conference on Force, Mass and Torque

Place:
Istanbul, TURKEY
Time:
17 September 2001 - 21 September 2001