Indirect Measurements on the Capacity in the Electrostatic HB Model |
|---|
| Oana Neacsu, A. Salceanu, E. Lunca, V. David |
- Abstract:
- Considering the classic HBM, for the associated human body capacitance (HBC) is generally accepted the value of 100 pF. Developing a method based on the charge preservation and using the Model 6517A as electrometer, we measured for HBC values spread between 50 and 500 pF. This quasi-large dispersion encouraged us to emit and to experimentally verify assumptions regarding the effective values of the HBC, according to different states, circumstances and accepted models. There is good accordance between measured and expected data. One conclusion might be that the classic HBM is rather a conventional and traditional testing standard than a real world universal circuit.
- Download:
- IMEKO-TC4-2007-120.pdf
- DOI:
- -
- Event details
- IMEKO TC:
- TC4
- Event name:
- TC4 Symposium 2007
- Title:
- XVth IMEKO TC4 International Symposium on Novelties in Electrical Measurements and Instrumentation (together with 12th IMEKO TC4 Workshop on ADC Modelling and Testing)
- Place:
- Iasi, ROMANIA
- Time:
- 19 September 2007 - 21 September 2007